Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Orthopedics ; : 1-5, 2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38147493

RESUMO

OBJECTIVE: A possible impairment in hip proprioception after total hip arthroplasty (THA) has been an issue of concern. The aims of this study were to investigate the extent of early postoperative change in standing hip rotation angle (HRAng) in patients with osteoarthritis (OA) undergoing THA and to consider a possible mechanism behind this. MATERIALS AND METHODS: A total of 82 hips (82 patients; 63 women and 19 men) undergoing unilateral primary THA with total capsulectomy were included. We characterized the standing HRAng and internal/external range of motion (ROM) in the prone position before THA and 2 weeks after THA. Acetabular/cup and femoral/stem anteversion, combined anteversion (CA), and leg length discrepancy were also characterized. Correlations were examined postoperatively between the HRAng and the other analyzed variables. RESULTS: The median standing HRAng showed a significant internal shift from external to more medial position (6.3° to 1.7°) 2 weeks after THA (P<.0001). The postoperative change in standing HRAng was significantly negatively correlated with the difference between the postoperative femoral anteversion and the stem anteversion (rs=-0.429, P<.0001) and with the pre- to postoperative change in CA (rs=-0.3012, P=.0063). CONCLUSION: This study demonstrated that the extent of the rotational shift of the distal femur toward medial direction was significantly associated with increasing stem anteversion and CA. This phenomenon can be interpreted as a compensatory mechanism for maintaining the relative positional relationship between the pelvis and the proximal femur using proprioception. Therefore, we conclude that the extracapsular/extra-articular components may be prominent determinants of joint position sense. [Orthopedics. 202x;4x(x):xx-xx.].

2.
Life (Basel) ; 13(7)2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37511990

RESUMO

BACKGROUND: The aims of this study are as follows: (1) to investigate the level and probability of bacterial contamination on scrub suits over time for medical personnel working inside and/or outside the operating room (OR) area; (2) to discuss the protective role of cover gowns against bacterial contamination; and (3) to consider the necessity of changing into clean suits whenever entering the OR in terms of preventing periprosthetic joint infection (PJI) in total joint replacement (TJR). METHODS: The bacterial colony count was examined on the chest area of the scrub suits worn during various daily clinical practices. The genus/species of the contaminants were identified by matrix-assisted laser deposition ionization-time of flight mass spectrometry (MALDI-TOF MS). RESULTS: The scrub suits worn outside the OR area showed a greater level of bacterial contamination than those worn inside the OR area, although the colony counts tended to increase over time both in and out of the area. The probability of contamination involving coagulase-negative staphylococci (CNS) (known as the primary cause of PJI) did not increase significantly in the scrubs worn inside the OR area, but did increase significantly after a long-time departure from the OR area. CONCLUSIONS: Our results suggest that wearing scrub suits outside and/or the long duration of wearing the same suits can significantly increase the level and probability of any bacterial contamination (including CNS) on scrub suits. We also found that wearing a cover gown over scrub suits outside the OR area may have only a limited protective role against bacterial contamination.

3.
Arch Orthop Trauma Surg ; 143(12): 7195-7203, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37438580

RESUMO

INTRODUCTION: An acetabular liner thickness of around 6 mm remains the "gold standard" in total hip arthroplasty. Some surgeons have been recommending the use of the thickest possible liner because contact stress and strain in articulating surfaces decrease with increasing the wall thickness. The purpose of this study was to determine whether in vivo creep and wear performance could be enhanced using a thicker liner over the standard thickness in vitamin-E-diffused highly crosslinked polyethylene (HXLPE). MATERIALS AND METHODS: One hundred and twenty-two hips were allocated to age-matched, sex-matched, and body mass index-matched two subgroups implanted either with a 6.8- or 8.9-mm-thick vitamin-E-diffused HXLPE liner against 28-mm cobalt-chrome femoral head, and followed-up for 7 years. Linear and volumetric penetration of femoral head into the liners attributed to creep and wear were analyzed for each group. RESULTS: Compressive creep strain generated at the initial 6 months was significantly larger in the 6.8-mm group (2.6%) than in the 8.9-mm group (2.2%). The linear steady-state wear observed after 2 years was 0.0019 and 0.0015 mm/year, whereas the volumetric steady-state wear was 0.54 and 0.45 mm3/years in the 6.8- and 8.9-mm-thick groups, respectively. Although less strain in the thicker group resulted in a slightly less wear, it did not reach significant differences in the steady-state wear rates between the groups. CONCLUSION: No clinical significance for using a thicker liner over the standard thickness (6.8 mm → 8.9 mm) was confirmed in the vitamin-E-diffused HXLPE according to the 7-year follow-up. The wear rates for both thicknesses were very low enough to prevent osteolysis, and no mechanical failure was observed at any follow-up interval. Nevertheless, since the significantly higher strain was seen in the thinner liner, further follow-up is needed to compare the longer term wear and the incidence of osteolysis and component fracture.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Criança , Artroplastia de Quadril/efeitos adversos , Polietileno , Vitamina E , Osteólise/etiologia , Falha de Prótese , Desenho de Prótese , Prótese de Quadril/efeitos adversos , Vitaminas , Seguimentos
4.
J Orthop Surg Res ; 18(1): 147, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36849999

RESUMO

BACKGROUND: Adverse local tissue reactions have been problematic as an implant-related complication in total hip arthroplasty (THA). Despite the absence of significant metal wear and corrosion, granulomatous pseudotumor has been reported to be caused by polyethylene wear. We performed a long-term follow-up study investigating the relationship between polyethylene wear and pseudotumor formation in THA. METHODS: This study included 57 patients (64 hips) that underwent primary THA with metal-on-polyethylene or ceramic-on-polyethylene bearing over a minimum follow-up of 15 years. They were stratified into pseudotumor and non-pseudotumor groups and their linear wear rates of polyethylene liner and serum cobalt (Co) and chromium (Cr) ion levels were compared. Pseudotumor was diagnosed on metal artifact reduction sequence-MRI according to its composition and wall thickness using the Hauptfleisch classification. RESULTS: The incidence of pseudotumor was 34% (22/64 hips) at the mean follow-up of 16.9 years. Metal ion levels did not differ between the pseudotumor and non-pseudotumor groups, and none of the patients exceeded the Co/Cr ratio of 2.0 µg/L. Moreover, the wear rate in the pseudotumor group was 1.8 times greater than in the non-pseudotumor group (0.14 vs. 0.08 mm/year, P < 0.001). According to an analysis of the receiver operating characteristic curves, the cutoff level of the wear rate to discriminate between pseudotumor and non-pseudotumor patients at 15 years was 0.11 mm/year (area under the curve = 91%; sensitivity = 95%; specificity = 78%; accuracy = 87%). CONCLUSIONS: Our results might provide new insights into excessive polyethylene wear potentially leading to the future development of both pseudotumor and osteolysis. Further studies are needed to clarify the direct relationship between polyethylene wear and pseudotumor and the mutual effects of osteolysis and pseudotumor in particle reactions.


Assuntos
Artroplastia de Quadril , Osteólise , Humanos , Polietileno/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Seguimentos , Cerâmica , Complicações Pós-Operatórias
5.
J Orthop Sci ; 27(4): 798-803, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34090777

RESUMO

BACKGROUND: The present study aimed to identify risk factors for preoperative nasal carriage of resistant bacteria - MRSA methicillin-resistant Staphylococcus (S.) aureus, MRSE (methicillin-resistant Staphylococcus epidermidis), and MRCNS (methicillin-resistant coagulase negative staphylococci) in total hip and knee arthroplasty (THA and TKA) patients. METHODS: Nasal cultures were obtained from 538 patients before THA (262 primary and 26 revision) and TKA (241 primary and 9 revision). These were classified either as methicillin-resistant bacteria (group MR) or methicillin-susceptible bacteria (including culture-negative) (group MS). Patient characteristics were compared between these groups using logistic regression models. RESULTS: The resistant bacteria were preoperatively present in 33.1% (178 patients) among all patients. MRSE, MRCNS, and MRSA were detected in 27.5% (148 patients), 3.7% (20 patients), and 1.9% (10 patients). In the unadjusted comparisons of the patient characteristics between the groups MR and MS, a significant difference was found in the percentages of diabetic patients (15.2% vs. 9.2%, P = 0.04); the association remained after the multivariable adjustment for possible risk factors (P < 0.001). In addition, the diabetic patients in the group MR showed a higher percentage of receiving insulin injection than those in the group MS (25.9% vs. 6.1%, P = 0.063), and their mean levels of HbA1c were significantly higher in the group MR than the MS (6.8% vs. 6.4%, P = 0.03). CONCLUSIONS: We identified diabetes as a risk factor for the preoperative nasal carriage of resistant bacteria. Our results suggest that, in order to prevent a surgical site infection (SSI), extra care should be taken in performing joint arthroplasties for diabetic patients, especially using insulin and with high HbA1c levels (≥6.6%) prior to the surgical procedures.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Insulinas , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Antibacterianos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Hemoglobinas Glicadas , Humanos , Meticilina , Resistência a Meticilina , Fatores de Risco , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus
6.
Orthop Surg ; 14(2): 264-273, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34910382

RESUMO

OBJECTIVE: To investigate the long-term survivorship, incidence of adverse reactions to metal debris (ARMD), and metal ion behavior in patients who underwent small-head Metasul metal-on-metal (MoM) total hip arthroplasty (THA). METHODS: Between February 1998 and September 2003, a retrospective study was performed on 43 consecutive patients (43 hips) who underwent unilateral cementless Metasul MoM THAs at our institution. Of them, 35 patients (nine males and 26 females) who were available for follow-up more than 15 years after THA were enrolled in this study and underwent metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) to identify ARMD. The mean age at surgery of the patients was 59.7 years old (range, 31-83). Clinical and radiographic outcomes were evaluated retrospectively. Clinical examinations were conducted using the Harris Hip Score (HHS). Serum cobalt (Co) and chromium (Cr) ion levels and Co/Cr ratio were assessed at different postoperative periods of <5, 5-10, 11-14, and ≥15 years. RESULTS: The mean follow-up period for the 35 patients included was 18.1 years (range, 15-22). The mean HHS significantly improved from 44.6 ± 11.3 points preoperatively to 89.4 ± 7.9 points at the final follow-up (P < 0.0001). ARMD was found in 20% of the patients using MARS-MRI. No signs of stem loosening were found clinically or radiographically, whereas cup loosening and ARMD were observed in three patients (9%), for whom revision THAs were performed. The Kaplan-Meier survival rates with revision for any reason as the endpoint were 90.9% at 5 years, 84.8% at 10 years, 84.8% at 15 years (95% CI, 67.1-93.6), and 70.3% at 20 years (95% CI, 43.6-87.0). The survival rates with revision for ARMD as the endpoint were 100% at 5 years, 96.6% at 10 years, 96.6% at 15 years (95% CI, 77.2-99.7), and 80.1% at 20 years (95% CI, 45.3-95.2). Serum Co ion level peaked at 5-10 years after THA, which was significantly higher than that <5 years; however, it decreased to the initial level after 15 years. In contrast, serum Cr ion level significantly increased at 5-10 years and then remained almost constant. Significant differences in Cr ion levels (1.0 vs 2.0 µg/L, P = 0.024) and Co/Cr ratio (1.3 vs 0.9, P = 0.037) were found between non-ARMD and ARMD patients at >11 years postoperatively. CONCLUSION: Our results suggest that increased Cr ion levels and decreased Co/Cr ratio may be signs of ARMD in patients who underwent small-head Metasul MoM THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Cobalto , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
7.
Arthroplast Today ; 11: 15-19, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34409142

RESUMO

We present a rare case of symptomatic adverse local tissue reaction in a 54-year-old female patient who had undergone total hip arthroplasty with ceramic-on-ceramic bearing. Inflammatory periarticular mass and osteolysis developed in the absence of cobalt chrome alloy interfaces and a modular neck component. On the pathologic images, there was no clear evidence of gross metal staining of tissues, metal corrosion, and ceramic or metal wear particles. However, there were impingement scars on the titanium alloy femoral neck and acetabular cup associated with a high combined anteversion angle of 75° (stem: 40° and cup: 35°), suggesting titanium debris release in vivo. Immunohistochemical staining proved a predominant infiltration of CD4+ T cells and the corresponding IL-17A response to metal. We conclude that neck-rim impingement may lead to the development of adverse local tissue reaction (periarticular mass and osteolysis) due to a metal hypersensitivity with the production of proinflammatory cytokines (IL-17A) by CD4+ T cells even in ceramic-on-ceramic total hip arthroplasty.

8.
Arthroplasty ; 3(1): 35, 2021 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-35236467

RESUMO

BACKGROUND: Gradual compression stocking (GCS) and intermittent pneumatic compression device (IPCD) are used for intraoperative mechanical prophylaxis against venous thromboembolism (VTE) during total knee arthroplasty (TKA). In this study, we applied a passive-assisted ankle motion in combination with GCS and IPCD during TKA and evaluated its effectiveness in preventing postoperative VTE. METHODS: We included 77 patients who underwent primary unilateral TKA. Patients were divided into group A (53 patients who underwent GCS and IPCD on their non-surgical side limb) and group B (24 patients who underwent passive ankle dorsiflexion motion in addition to GCS and IPCD on their non-surgical side limb). Deep vein thrombosis (DVT) was assessed using lower extremity ultrasonography (US). The incidence of VTE in each affected limb was compared between the two groups. RESULTS: US was performed 4 days after surgery on average. The incidence of DVT in groups A and B was 47.2 and 70.8 %, respectively. In group A, 22.6 % of DVTs were found only on the surgical side, 11.3 % on the non-surgical side, and 13.2 % on both sides. On the other hand, in group B, 41.7 % of DVTs were found only on the surgical side, 4.2 % on the non-surgical side, and 25.0 % on both sides. No significant difference in the incidence of VTE was noted between the 2 groups. CONCLUSIONS: The intraoperative application of passive ankle motion plus GCS and IPCD might not further reduce the incidence of postoperative DVT in TKA patients.

9.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020976232, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33355037

RESUMO

BACKGROUND: In view of preventing surgical site infection (SSI) in the orthopedic operating room (OR), evidence concerning types of footwear and clothing is limited. This study aimed to investigate how different footwear and clothing affect the cleanliness of the OR environment. METHODS: The airborne dust concentration in a bioclean room (NASA class 100) was measured around an operator by using a handheld particle counter under the following conditions: (I) wearing a sterilized full-type space suit with OR dedicated clean sandals; (II) wearing a sterilized full-type space suit with non-dedicated (outside) shoes or severely contaminated outside shoes with surgical glove powder (2 µm mean particle size); and (III) wearing an unsterilized medical scrub uniform with OR dedicated sandals. The participant was standing still or stepping in place at 1 Hz during the testing. RESULTS: The concentrations of airborne dusts in the operative field were independent of footwear and clothing types under the stand-still condition. However, these values significantly increased 1.96- to 16.23-fold after simple stepping motion in all the test conditions, and often became dissatisfaction level with the NASA100 requirement for the OR cleanliness. The worst contamination occurred when an operator wore the powder-contaminated shoes and also the unsterilized scrub uniform. CONCLUSION: The present study showed that the stepping motion triggered a considerable contamination in the operative field (beyond the level of NASA100 threshold) particularly when an operator used the outside shoes or unsterilized scrub uniform. Therefore, these results tell us that the one-footwear system (i.e., no use of OR dedicated clean shoes) and unsterilized scrub are likely to be a potential risk factor for SSI. Nevertheless, further studies are necessary to conclude the real efficacy of OR dedicated shoes and sterilized clothes on the SSI prevention.


Assuntos
Salas Cirúrgicas/provisão & distribuição , Sapatos , Posição Ortostática , Infecção da Ferida Cirúrgica/prevenção & controle , Humanos , Período Intraoperatório , Fatores de Risco
10.
Arthroplast Today ; 6(3): 526-531, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32743035

RESUMO

We describe 2 cases of pseudotumors induced by an unusual size of polyethylene wear particle after metal-on-polyethylene total hip arthroplasty (MoP THA). The supra-macroparticles of size >100 µm originated from a polyethylene liner with relatively small cup anteversion, potentially leading to excessive loading and increased wear of the anterior edge of the polyethylene liner. Histopathology showed a foreign-body reaction to the polyethylene particles without an adverse reaction to metal debris and with no severe signs of corrosion at the head-neck junction, which have been noted in past reports of pseudotumors in MoP THA. It has been suggested that the large polyethylene wear particles might be the cause of pseudotumor formation in MoP THA.

11.
J Orthop Surg (Hong Kong) ; 28(2): 2309499020918317, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32329384

RESUMO

BACKGROUND: It is important to understand postoperative global sagittal spinal alignment after total hip arthroplasty (THA) to prevent not only the following hip complications but also progressing lumbar degeneration. The purpose of this study was to progress the analysis of the global sagittal spinal alignment between before and after THA in patients without large lower limbs discrepancy. SUBJECTS AND METHODS: The subjects were 87 patients with bilateral hip osteoarthritis (OA) before unilateral primary THA. We measured sagittal vertical axis (SVA), lumbar lordotic angle, sacral slope, pelvic tilt (PT), and pelvic incidence (PI) and compared the postoperative change of those parameters. Excluded criteria were Crowe classification types II, III, and IV and more than 10 mm of leg length difference, spinal scoliosis (Cobb angle > 25°), and lumbar kyphosis. RESULTS: The correlation coefficient between preoperative factors and postoperative sagittal alignments revealed that postoperative SVA has correlation with age (r = 0.46, p < 0.008) and preoperative PT (r = 0.42, p = 0.015). Postoperative PT had a correlation with preoperative PI (r = 0.46, p = 0.007). The change of PT after operation had negative correlation to preoperative PT (r = -0.47, p < 0.01) and PI (r = -0.38, p = 0.03). Multiple regression analysis revealed that the change of PT = 4.979 - 0.235 × preoperative PT (p < 0.05). Therefore, when preoperative PT was less than 20°, the postoperative PT would become larger than the preoperative one. CONCLUSION: (1) In patient with hip OA without large lower limbs discrepancy, the postoperative PT after THA correlated with PI. (2) The postoperative change of PT was influenced by preoperative PT.


Assuntos
Artroplastia de Quadril/métodos , Osteoartrite do Quadril/cirurgia , Postura/fisiologia , Idoso , Feminino , Humanos , Masculino , Osteoartrite do Quadril/fisiopatologia , Período Pós-Operatório
12.
J Orthop Surg (Hong Kong) ; 27(2): 2309499019848095, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31084257

RESUMO

PURPOSE: The purpose of the present study was to follow up Japanese patients with deep vein thrombosis (DVT) after total knee arthroplasty (TKA) and also to examine factors associated with residual thrombus within the sixth postoperative month. METHODS: DVT evaluation was performed by noninvasive venous ultrasonography. We retrospectively reviewed 88 Japanese patients (88 knees) receiving primary unilateral TKA, who had no preoperative DVT. We examined the influence of the following four factors on postoperative DVT: (1) patient factors (age, sex, body height, body weight, and body mass index), (2) surgical factors (operation time, bleeding amount, avascularization time, and anesthesia method), (3) postoperative factors (bleeding amount, period to ambulation, period of venous foot pump use, and ratio of graduated compression stocking use), and (4) DVT conditional factors (location, length, number of vein branches, and the presence of >5 mm vasodilatation). RESULTS: The total prevalence of venous thromboembolism (VTE) was 62.5% (55 of the 88 patients). Among the 55 VTE patients, the rates of distal and proximal DVT were 96.4% and 3.6%, respectively. Bilateral DVT was found in 34.5%, while unilateral DVT on the surgical and nonsurgical sides were 52.7% and 12.7%, respectively. Asymptomatic pulmonary embolism was 1.8%. DVT was exacerbated in five patients (11.9%), of whom three showed additional thrombus formation. The remaining two patients had thrombus elongation or propagation from distal to proximal veins. In comparisons between thrombus-unresolved and -resolved groups within the sixth postoperative month, statistical significances were found in the incidence of bilateral DVT (50.0% vs. 15.4%, p = 0.02) and unilateral DVT (43.8% vs. 76.9%, p = 0.02). On the other hand, operation time (107.0 ± 17.3 min vs. 94.5 ± 11.9 min, p = 0.01) and avascularization time (99.8 ± 17.6 min vs. 88.0 ± 11.5 min, p = 0.01) in bilateral DVT patients were significantly longer than in unilateral ones. CONCLUSION: Our results suggest that an extended operation and avascularization time may be a risk factor for bilateral DVT and residual thrombus over 6 months.


Assuntos
Artroplastia do Joelho/efeitos adversos , Complicações Pós-Operatórias/etiologia , Ultrassonografia/métodos , Trombose Venosa/etiologia , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Trombose Venosa/diagnóstico , Trombose Venosa/epidemiologia
13.
J Orthop ; 15(1): 134-137, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29657457

RESUMO

We investigated the effects of varus-valgus alignment on the long-term outcomes after cementless total hip arthroplasty (THA) using a porous coated version of Bi-Metric® femoral stems. The Kaplan-Meier survival analysis was performed in 71 hips. The survival rate with femoral revision for aseptic loosening as the end point was 100% at 17 years. Nevertheless, the initial stem alignment was more valgus in patients with the Engh grade III-IV stress shielding than patients with the Engh grade I-II. Our results suggest that valgus misalignment of cementless Bi-Metric stem might be a potential risk factor for the progression of stress shielding.

14.
Ther Clin Risk Manag ; 11: 1383-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26396523

RESUMO

It has been recognized that perioperative hemostasis management after joint-replacement surgery for hemophilia patients is complicated and cumbersome, due to the necessity of rigorous monitoring for clotting-factor levels throughout the infusion. Between 2005 and 2014, we examined seven patients with hemophilia A (ten joints: six hips and four knees) receiving total hip or knee arthroplasty (THA or TKA) for hemophilic arthropathy. One male patient (31 years old) showed an intra-articular hematoma formation after THA (case 1). In another male patient (46 years old) receiving TKA, the postoperative trough factor VIII level became lower significantly than reference levels (80%-100% for the 5-10 postoperative days) recommended by the guidelines from the Japanese Society on Thrombosis and Hemostasis, despite sufficient coagulant based on the guidelines being administered (case 2). In the latter patient, deep infection and hematoma formation were observed postoperatively. In this article, we provide a detailed clinical report regarding these two complication cases at the early postoperative periods, and the management of bleeding control for hemophilia patients is discussed.

15.
J Biomed Mater Res B Appl Biomater ; 91(2): 887-896, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19598291

RESUMO

Our 32 and 38 mm alumina ceramic-on-metal (COM) bearings were run in a hip simulator study for comparison with 32 mm metal-on-metal (MOM) controls. The 32 mm MOM bearings demonstrated an overall wear rate of 1.58 mm(3)/million cycles (Mc) that was comparable to previous simulator studies. The peak run-in MOM wear-rates (10, 15.7 mm(3)/Mc) were higher than in previous simulator studies. There was a noticeable graying in color of serum lubricants with MOM wear rates of 2-3 mm(3)/Mc and with wear rates of 10-15 mm(3)/Mc the serum became much darker. The COM lubricants darkened during two "break-away" wear events with wear-rates 5.8-6.7 mm(3)/Mc. The 32 and 38 mm COM bearings demonstrated overall wear-rates of 0.38 and 0.29 mm(3)/Mc, approximately four-fold reduced compared to MOM controls. The COM wear-rates were also much higher than in the one previous COM study. There may be methodological reasons that could explain this discrepancy. Our ion concentrations assessed from serum lubricants had Cobalt (Co) 68% and Chromium (Cr) 32% for average ratio of metal ion composition (i.e. averaging Co/Cr ratios: 2.26) in the parent alloy. Comparing Co ion concentrations during run-in, the COM bearings represented a 35-fold reduction compared to MOM. At 3.0 Mc, the COM represented a 33-fold reduction compared to MOM. Overall, our simulator study confirmed previously published advantages of low wear and reduced metal ions with the ceramic-metal coupling compared to standard metal-metal bearings.


Assuntos
Cerâmica/química , Prótese de Quadril , Metais/química , Óxido de Alumínio/química , Cromo/química , Cobalto/química , Cor , Cabeça do Fêmur/anatomia & histologia , Lubrificantes , Lubrificação , Teste de Materiais , Molibdênio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...